![hantek 6022be oscilloscope software hantek 6022be oscilloscope software](https://alitools.io/en/showcase/image?url=https%3A%2F%2Fae01.alicdn.com%2Fkf%2FH48be9006646545348542bf19c2c68ddb3.jpg)
- Hantek 6022be oscilloscope software install#
- Hantek 6022be oscilloscope software drivers#
- Hantek 6022be oscilloscope software update#
- Hantek 6022be oscilloscope software full#
- Hantek 6022be oscilloscope software software#
The first, easy thing to try, is once the Hantek software is working, try reinstalling BasicScope. This may require a bit of detective work. I have to admit, I never tried the program on Windows 10, but if the Hantek software works, then I think there’s hope for BasicScope. Added more info to saved trace for bug reporting purposesīasicScope 0.13 binary for Windows XP (32-bit)īasicScope 0.13 source for Visual Studio 2010 ExpressĮnhanced (best guess) documentation for HTMarch_dllĮnhanced (best guess) documentation for HTDisplayDll.
Hantek 6022be oscilloscope software full#
For example, if the scope is ±5 volts full scale, the user could set a trigger level of 6 volts, causing the scope to never trigger Starting with version 0.14, there is a warning posted in the tooltip for the trigger level.
![hantek 6022be oscilloscope software hantek 6022be oscilloscope software](http://pididu.com/wordpress/wp-content/uploads/2013/08/6022BE.jpg)
Otherwise identical to previous build.īasicScope 0.17 source for Visual Studio 2010 Express
![hantek 6022be oscilloscope software hantek 6022be oscilloscope software](https://sc01.alicdn.com/kf/HTB1uY8hGXXXXXcHXVXXq6xXFXXXj/200870242/HTB1uY8hGXXXXXcHXVXXq6xXFXXXj.jpg)
![hantek 6022be oscilloscope software hantek 6022be oscilloscope software](https://sc04.alicdn.com/kf/Hf203cbfa26104eedbd0ac85e51d18965X.jpg)
When enabled, every trace is saved in data.csv (or file of user’s choice), unless that file already exists.īasicScope 1.2 source for Visual Studio 2010 Express Data Acquisition Mode added for interface with 3rd party programs.If the problem still exists after the update, please let me know.BasicScope 1.3 source for Visual Studio 2010 Express oem files (which may contain these"USB\VID_04B4&PID_602A.DeviceDesc%=Hantek6022BL1.Dev, USB\VID_04B4&PID_602A Go to this path (C:\Windows\INF) and find the new. Go to this path (C:\Windows\System32\drivers) and find the file (Hantek6022BLAMD641.SYS/Hantek6022BLAMD642.SYS). I am at the stage of replacing the PC Oscilloscope with another brand as this is totally frustrating.Are you able to help?
Hantek 6022be oscilloscope software drivers#
While the 6022BL is plugged into a USB port the PC crashes.The 6022BL has the button pressed in at the rear of the instrument.If I remove the 6022 from the USB the system stops crashing but from now on there is no way to remove the faulty driver as if I plug the PC Oscilloscope in to the USBWindows 10 crashes immediately.Thankfully I do a complete System backup before trying to reinstall Hantek driver.Įven though I am installing the English drivers Windows asks whether I trust this software.Image is attached.ĭo you have signed drivers and something that will work and not crash Windows 1064bit.? Stop Code: SYSTEM THREAD_EXCEPTION NOT HANDLED The driver installed and for a brief second I saw the Windows message saying that the device was correctly installed.Ībout 1-2 seconds later the Windows blue screen appears with the message:
Hantek 6022be oscilloscope software update#
I followwed the update driver instructions as listed in this forum and pointed to the driver folder.Įven though I am installing the English drivers Windows asks whether I trust this software (labelled in Chinese).Image is attached.
Hantek 6022be oscilloscope software install#
I have tried a number of methods of installling drivers for the 6022BL model under Windows 10 (64 bit).On two previous computers it involved installing Saleae Logic Analyser drivers and also changing the startup behaviour of Windows 10 to accept non-signed drivers.On my rebuilt new Windows 10 hardware I have had failure after failure.įrom this forum site I downloaded the drivers and expanded them.I didnt install the Hantek Software at this stage.Īfter plugging in the PC Oscilloscope Device manager reported an unknown device an error I expected. Publish time 08:11:33 Hantek 6022BL driver install crashes Windows 10